Schneider TM221CE16T logic controller
Specifications
Range of product | Modicon M221 |
---|---|
Product or component type | Logic controller |
[Us] rated supply voltage | 24 V DC |
Discrete input number | 9, discrete input 4 fast input conforming to IEC 61131-2 Type 1 |
Analogue input number | 2 at 0...10 V |
Discrete output type | Transistor |
Discrete output number | 7 transistor 2 fast output |
Discrete output voltage | 24 V DC |
Discrete output current | 0.5 A |
Discrete I/O number | 16 |
---|---|
Maximum number of I/O expansion module |
4 (local I/O-Architecture) 11 (remote I/O-Architecture) |
Supply voltage limits | 20.4…28.8 V |
Inrush current | 35 A |
Maximum power consumption in W |
11 W at 24 V (with max number of I/O expansion module) 4.6 W at 24 V (without I/O expansion module) |
Power supply output current |
0.325 A 5 V for expansion bus 0.15 A 24 V for expansion bus |
Discrete input logic | Sink or source (positive/negative) |
Discrete input voltage | 24 V |
Discrete input voltage type | DC |
Analogue input resolution | 10 bits |
LSB value | 10 mV |
Conversion time | 1 ms per channel + 1 controller cycle time for analogue input analog input |
Permitted overload on inputs |
+/- 30 V DC for 5 min (maximum) for analog input +/- 13 V DC (permanent) for analog input |
Voltage state 1 guaranteed | >= 15 V for input |
Voltage state 0 guaranteed | <= 5 V for input |
Discrete input current |
7 mA for discrete input 5 mA for fast input |
Input impedance |
3.4 kOhm for discrete input 100 kOhm for analog input 4.9 kOhm for fast input |
Response time |
35 µs turn-off, I2...I5 terminal(s) for input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input 35 µs turn-on, other terminals terminal(s) for input 5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input 100 µs turn-off, other terminals terminal(s) for input 5 µs turn-on, turn-off, Q0...Q1 terminal(s) for output 50 µs turn-on, turn-off, Q2...Q3 terminal(s) for output 300 µs turn-on, turn-off, other terminals terminal(s) for output |
Configurable filtering time |
0 ms for input 3 ms for input 12 ms for input |
Discrete output logic | Positive logic (source) |
Maximum current per output common | 3.5 A |
Output frequency |
100 kHz for fast output (PWM/PLS mode) at Q0...Q1 5 kHz for output at Q2...Q3 0.1 kHz for output at Q4...Q6 |
Absolute accuracy error | +/- 1 % of full scale for analog input |
Maximum leakage current | 0.1 mA for transistor output |
Maximum voltage drop | <1 V |
Mechanical durability | 20000000 cycles for transistor output |
Maximum tungsten load | <12 W for output and fast output |
Protection type | Overload and short-circuit protection at 1 A |
Reset time | 1 s automatic reset |
Memory capacity |
256 kB for user application and data RAM with 10000 instructions 256 kB for internal variables RAM |
Data backed up | 256 kB built-in flash memory for backup of application and data |
Data storage equipment | 2 GB SD card (optional) |
Battery type | BR2032 or CR2032X lithium non-rechargeable |
Backup time | 1 year at 25 °C (by interruption of power supply) |
Execution time for 1 KInstruction | 0.3 ms for event and periodic task |
Execution time per instruction | 0.2 µs Boolean |
Exct time for event task | 60 µs response time |
Maximum size of object areas |
512 %M memory bits 255 %C counters 512 %KW constant words 255 %TM timers 8000 %MW memory words |
Realtime clock | With |
Clock drift | <= 30 s/month at 25 °C |
Regulation loop | Adjustable PID regulator up to 14 simultaneous loops |
Positioning functions |
Position PTO 2 axe(s)pulse/direction mode (100 kHz) Position PTO 1 axe(s)CW/CCW mode (100 kHz) |
Function available |
PWM Frequency generator PLS |
Counting input number | 4 fast input (HSC mode) at 100 kHz 32 bits |
counter function |
Single phase A/B Pulse/direction |
Integrated connection type |
USB port with mini B USB 2.0 connector Non isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface Ethernet with RJ45 connector |
Supply | (serial)serial link supply: 5 V, <200 mA |
Transmission rate |
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 480 Mbit/s for USB |
Communication port protocol |
USB port: USB - SoMachine-Network Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network Ethernet |
Port Ethernet | 10BASE-T/100BASE-TX 1 port with 100 m copper cable |
Communication service |
Modbus TCP client DHCP client Modbus TCP slave device Modbus TCP server Ethernet/IP adapter |
Local signalling |
1 LED (green) for PWR 1 LED (green) for RUN 1 LED (red) for module error (ERR) 1 LED (green) for SD card access (SD) 1 LED (red) for BAT 1 LED per channel (green) for I/O state 1 LED (green) for SL Ethernet network activity (green) for ACT Ethernet network link (yellow) for Link (Link Status) |
Electrical connection |
removable screw terminal block for inputs removable screw terminal block for outputs terminal block, 3 terminal(s) for connecting the 24 V DC power supply connector, 4 terminal(s) for analogue inputs Mini B USB 2.0 connector for a programming terminal |
Maximum cable distance between devices |
Shielded cable: <10 m for fast input Unshielded cable: <30 m for output Unshielded cable: <30 m for digital input Unshielded cable: <1 m for analog input Shielded cable: <3 m for fast output |
Insulation |
Between input and internal logic at 500 V AC Between fast input and internal logic at 500 V AC Non-insulated between inputs Between output and internal logic at 500 V AC Non-insulated between analogue input and internal logic Non-insulated between analogue inputs |
Marking | CE |
Mounting support |
Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 plate or panel with fixing kit |
Height | 90 mm |
Depth | 70 mm |
Width | 95 mm |
Net weight | 0.346 kg |
Standards |
IEC 61131-2 UL 508 CAN/CSA C22.2 No. 213 IACS E10 ANSI/ISA 12-12-01 |
---|---|
Product certifications |
EAC DNV-GL RCM ABS cULus LR CE UKCA cULus HazLoc |
Environmental characteristic | Ordinary and hazardous location |
Resistance to electrostatic discharge |
8 kV in air conforming to IEC 61000-4-2 4 kV on contact conforming to IEC 61000-4-2 |
Resistance to electromagnetic fields |
10 V/m 80 MHz...1 GHz conforming to IEC 61000-4-3 3 V/m 1.4 GHz...2 GHz conforming to IEC 61000-4-3 1 V/m 2...2.7 GHz conforming to IEC 61000-4-3 |
Resistance to magnetic fields | 30 A/m 50/60 Hz conforming to IEC 61000-4-8 |
Resistance to fast transients |
2 kV (power lines) conforming to IEC 61000-4-4 2 kV (relay output) conforming to IEC 61000-4-4 1 kV (I/O) conforming to IEC 61000-4-4 1 kV (Ethernet line) conforming to IEC 61000-4-4 1 kV (serial link) conforming to IEC 61000-4-4 |
Surge withstand |
2 kV power lines (AC) common mode conforming to IEC 61000-4-5 2 kV relay output common mode conforming to IEC 61000-4-5 1 kV I/O common mode conforming to IEC 61000-4-5 1 kV shielded cable common mode conforming to IEC 61000-4-5 0.5 kV power lines (DC) differential mode conforming to IEC 61000-4-5 1 kV power lines (AC) differential mode conforming to IEC 61000-4-5 1 kV relay output differential mode conforming to IEC 61000-4-5 0.5 kV power lines (DC) common mode conforming to IEC 61000-4-5 |
Resistance to conducted disturbances |
10 V 0.15...80 MHz conforming to IEC 61000-4-6 3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL) 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL) |
Electromagnetic emission |
Conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to IEC 55011 Conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to IEC 55011 Conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10…150 kHz conforming to IEC 55011 Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to IEC 55011 Radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to IEC 55011 Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to IEC 55011 Radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to IEC 55011 |
Immunity to microbreaks | 10 ms |
Ambient air temperature for operation |
-10…55 °C (horizontal installation) -10…35 °C (vertical installation) |
Ambient air temperature for storage | -25…70 °C |
Relative humidity |
10…95 %, without condensation (in operation) 10…95 %, without condensation (in storage) |
IP degree of protection | IP20 with protective cover in place |
Pollution degree | <= 2 |
Operating altitude | 0...2000 m |
Storage altitude | 0…3000 m |
Vibration resistance |
3.5 mm at 5…8.4 Hz on symmetrical rail 3.5 mm at 5…8.4 Hz on panel mounting 1 gn at 8.4…150 Hz on symmetrical rail 1 gn at 8.4…150 Hz on panel mounting |
Shock resistance | 147 m/s² for 11 ms |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 10.6 cm |
Package 1 Width | 14.0 cm |
Package 1 Length | 13.9 cm |
Package 1 Weight | 300.0 g |
Unit Type of Package 2 | S04 |
Number of Units in Package 2 | 20 |
Package 2 Height | 30 cm |
Package 2 Width | 40 cm |
Package 2 Length | 60 cm |
Package 2 Weight | 6.983 kg |
Unit Type of Package 3 | P12 |
Number of Units in Package 3 | 240 |
Package 3 Height | 105.0 cm |
Package 3 Width | 120.0 cm |
Package 3 Length | 80.0 cm |
Package 3 Weight | 156 kg |